OUR PROMISE; COMMITMENT TO QUALITY - RELIABILITY GUARANTEED
Model 30 – “High Volume”
Polymer Capacity - 1.7- 6 L/min. - 648 - 2280 gpd.
The fully automated Model 30 design works well for high-volume polymer for critical applications. The unit features a SS/Viton construction progressive cavity pump (optional gear pump) to ensure an accurate and reliable, non-pulsating, low shear supply of polymer to the SS Tri-Clamp Blending System. The Model 30’s dual dilution piping arrangement provides the highest polymer activation level. All systems come with low water flow, and polymer fail-safe devices, Industrial grade components, and controls, ensure years of trouble-free operation. Drip containment, client-specified parts, and control options available. Power supply 575, 460 VAC. Higher capacity system designs are available upon request.
Utilities
Inlet Water Flow | 600 LPM – 150 GPM |
Inlet Water Pressure (required) | 80 PSI Minimum |
Power Requirement | R575 - 460 VAC |
Polymer Consumption | 1050 Kg/day @ .5% Concentration |
w / Alternating Tank Configuration * AT | 1500 kg/d Yield |
PLC Standard | Allen Bradley MicroLogix |
HMI Standard | Allen Bradley PanelView Plus |
Tank Sizing w/Standard Transfer Pump
Polymer Usage/Day | Suggested Mix Tank Size (Working Volume) | STD. Transfer Rate |
---|---|---|
KG's | Liters | L/Min |
325 | 5m3 | 600 |
550 | 10m3 | 600 |
750 | 15m3 | 600 |
900 | 20m3 | 600 |
1000 | 25m3 | 600 |
1050 | 30m3 | 600 |
Standard Components:
- Piping 316 SS welded & flanged construction
- SS hopper assembly w/level sensor
- Double latch access door
- Removable safety screen
- TripKO Volumetric Feeder w/conditioner feeder w/VFD speed control
- SS HydraFlex Vacuum Wetting System w/overflow protection
- Magnetic flow meter – source water
- All required check valves 316 SS
- Electrical certification UL/CSA
Optional Options
- Piping 316 SS B31.3 construction
- Electric hoist & trolley
- Bulk bag conditioning
- Dust collector
- Client specified instruments & components
- Loss of weight feed systems
- Optional tank construction & configuration
- Electrical certification / CE
- Double latch access door w/viewing glass
- Knife gate hopper isolation valve
- Multi-stage booster pump
- Rapid Fill System