HydraFlex (HC) Series




  • Inlet Water Flow- 600 LPM – 150 GPM
  • Inlet Water Pressure (required)- 80 PSI Minimum
  • Power Requirement- 575 - 460 VAC
  • Polymer Consumption- 1050 Kg/day @ .5% Concentration

Details below

OUR PROMISE; COMMITMENT TO QULAITY - RELIABILITY GUARANTEED

Our HC (High Capacity) Dry Polymer System are capable of handling consumption rates of 1500 kg’s /3300 lbs./day.   We custom design larger systems by implementing rapid fill lines, tank, and mixer enhancements for higher-than-normal use applications.

We feature 3 basic designs:


These site-specific designs are often dependent on size constraints and client preference. They incorporate our HydraFlex wetting assembly, providing excellent polymer hydration and dust containment.

Operational Sequence - Mix Tank
  1. Water inlet valve opens.
  2. (Optional) booster pump starts.
  3. Flow rate confirmed.
  4. Tank water level rises, lower mixer propeller immersed.
  5. Mixer motor starts.
  6. Volumetric feeder starts & feeds polymer.
  7. At 80% tank level the feeder stops
  8. Water continues completes the fill cycle.
  9. The mixer continues until sufficient polymer hydration is achieved.
Operational Sequence - Application/Storage Tank
  1. Ratio to Mix tank best at 2:1 or more.
  2. Tank level drops to predetermined volume.
  3. Requires Sufficient capacity receive the entire contents of the mix tank

HC-200 Utilities

Inlet Water Flow 600 LPM – 150 GPM
Inlet Water Pressure (required) 80 PSI Minimum
Power Requirement 575 - 460 VAC
Polymer Consumption 1050 Kg/day @ .5% Concentration
w / Alternating Tank Configuration * AT 1500 kg/d Yield
PLC Standard Allen Bradley MicroLogix
HMI Standard Allen Bradley PanelView Plus

HC-100 Utilities

Inlet Water Flow 375 LPM – 100 GPM
Inlet Water Pressure (required) 80 PSI Minimum
Power Requirement 460/575 VAC
Polymer Consumption 700 Kg/day @ .5% Concentration
w / Alternating Tank Configuration * AT 1200 kg/d Yield
PLC Standard Allen Bradley MicroLogix
HMI Standard Allen Bradley PanelView Plus

Consistent and accurate feeding is critical for industrial and municipal large volume polymer applications. Our designs include a single feed and conditioning screw in all our HC Series Systems volumetric feeders. Hoppers also include a safety screen, a vibrator pad (vibrator optional) hermetically sealed knife gate isolation valve, dust collection hookups and an access hatch with viewing window with a heavy duty locking mechanism.

HC-200

Tank Sizing w/Standard Transfer Pump

Polymer Usage/Day Suggested Mix Tank Size (Working Volume) Std. Transfer Rate
KG's Liters L/Min
325 5m3 600
500 10m3 600
750 15m3 600
900 20m3 600
1000 25m3 600
1050 30m3 600
1250 *25m3/AT
1500 *30m3/AT

* Recommended 90-minute mix time.

HC-100

Tank Sizing w/Standard Transfer Pump

Polymer Usage/Day Suggested Mix Tank Size (Working Volume) Std. Transfer Rate
KG's Liters L/Min
300 5m3 375
500 10m3 375
600 15m3 375
700 20m3 375
750 25m3 375
1125 *25m3/AT
1200 *30m3/AT

Need Help?