Our HC (High Capacity) Dry Polymer System are capable of handling consumption rates of 1500 kg’s /3300 lbs./day.
We custom design larger systems by implementing rapid fill lines, tank, and mixer enhancements for higher-than-normal use applications.
We feature 3 basic designs:
These site-specific designs are often dependent on size constraints and client preference. They incorporate our HydraFlex wetting assembly, providing excellent polymer hydration and dust containment.
Operational Sequence - Mix Tank |
- Water inlet valve opens.
- (Optional) booster pump starts.
- Flow rate confirmed.
- Tank water level rises, lower mixer propeller immersed.
- Mixer motor starts.
- Volumetric feeder starts & feeds polymer.
- At 80% tank level the feeder stops
- Water continues completes the fill cycle.
- The mixer continues until sufficient polymer hydration is achieved.
|
Operational Sequence - Application/Storage Tank |
- Ratio to Mix tank best at 2:1 or more.
- Tank level drops to predetermined volume.
- Requires Sufficient capacity receive the entire contents of the mix tank
|
HC-200 Utilities
Inlet Water Flow |
600 LPM – 150 GPM |
Inlet Water Pressure (required) |
80 PSI Minimum |
Power Requirement |
575 - 460 VAC |
Polymer Consumption |
1050 Kg/day @ .5% Concentration |
w / Alternating Tank Configuration * AT |
1500 kg/d Yield |
PLC Standard |
Allen Bradley MicroLogix |
HMI Standard |
Allen Bradley PanelView Plus |
HC-100 Utilities
Inlet Water Flow |
375 LPM – 100 GPM |
Inlet Water Pressure (required) |
80 PSI Minimum |
Power Requirement |
460/575 VAC |
Polymer Consumption |
700 Kg/day @ .5% Concentration |
w / Alternating Tank Configuration * AT |
1200 kg/d Yield |
PLC Standard |
Allen Bradley MicroLogix |
HMI Standard |
Allen Bradley PanelView Plus |
Consistent and accurate feeding is critical for industrial and municipal
large volume polymer applications. Our designs include a single feed and
conditioning screw in all our HC Series Systems volumetric feeders. Hoppers
also include a safety screen, a vibrator pad (vibrator optional) hermetically
sealed knife gate isolation valve, dust collection hookups and an access hatch
with viewing window with a heavy duty locking mechanism.
HC-200
Tank Sizing w/Standard Transfer Pump
Polymer Usage/Day |
Suggested Mix Tank Size (Working Volume) |
Std. Transfer Rate |
KG's |
Liters |
L/Min |
325 |
5m3 |
600 |
500 |
10m3 |
600 |
750 |
15m3 |
600 |
900 |
20m3 |
600 |
1000 |
25m3 |
600 |
1050 |
30m3 |
600 |
1250 |
*25m3/AT |
|
1500 |
*30m3/AT |
|
* Recommended 90-minute mix time.
HC-100
Tank Sizing w/Standard Transfer Pump
Polymer Usage/Day |
Suggested Mix Tank Size (Working Volume) |
Std. Transfer Rate |
KG's |
Liters |
L/Min |
300 |
5m3 |
375 |
500 |
10m3 |
375 |
600 |
15m3 |
375 |
700 |
20m3 |
375 |
750 |
25m3 |
375 |
1125 |
*25m3/AT |
|
1200 |
*30m3/AT |
|